Airtec – Technical Specification/Properties
  Airtec-Single Airtec-Double
Thermal Resistance    
Bubble 0.125²K/W 0.125²K/W
Cavity 0.665²K/W 0.665²K/W
Total Thermal Resistance 0.790m²K/2 1.455m²K/2
Environmental CFC & HCFC Free CFC & HCFC Free
Dimensions    
Thickness 4mm 4mm
Width 1050mm/1200mm/1500mm 1050mm/1200mm/1500mm
Length 25m roll 25m roll
Airtec Foil Tape 50m x 75mm (24 rolls per box) 50m x 75mm (24 rolls per box)

 

Technical Refernce
  • Building Regulations 2000 Approved Documents L1 & L2.
  • Building Standards Part J Sept. 2001
  • BRE publication ‘Thermal Insulation: Avoiding the risks’.
  • BRE Paper IP12/94 ‘Assessing the Condensation Risk and Heat Loss at
    Thermal Bridges Around Openings’.
  • BS EN ISO 6946 : 1997 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method.
  • British Standard References: BS 5250 Control of Condensation in Buildings.
  • Emissivity measured by National Physical Laboratory.
  • Thermal resistance measured by Independent Test Laboratories.
  • Tested to BS EN 12153:2000 for water tightness and air permeability.
  • Manufactured in the UK and meeting the requirements of
    BS EN ISO 9002.

Condensation Risk
Further to calculating the thermal insulation requirements through a cavity wall, a check should be made for predicting the risk of condensation within the structure. This should be carried out using the method described in BS5250:1999.

 
Fully Certified
Meets NHBC Standards
Able to achieve U-Values of 0.27 New Build & Refurbishment
CFC/HCFC Free Fire Retardant Version Available
 