Press Releases Links
Home
Enquiries
Suppliers
Downloads
Contact

Products Overview | Cavity Closers | Therma-bridge Plus


Polyethylene Insulation DPC


Therma-Bridge - Technical Data
Total System Width (mm)
Insulation Width (mm)
For Return
Block (mm)
DPC Length (metres)
165
100
100
1.42, 2.50 or 5m Lengths
225
150
140
1.42, 2.50 or 5m Lengths
337
150
140/150
1.42, 2.50 or 5m Lengths
450
150
140/150
1.42, 2.50 or 5m Lengths

Other non-standard dpc and insulation widths are also available on request. Please contact us for details.

Performance Test Data of DPC
DPC to BS6515 (1984) High Performance Polyethylene

Performance Test Data of Insulation
ESP70 (Expanded Polystyrene) to BS EN 13163.
r value of product is 0.474 m:²K/W. (at 18mm thickness)
k value of Expanded Polystyrene is 0.038 W/mK.

Recommendations
All work should be carried out in accordance to BS5628:Part 3:1985.

Use of masonry, materials and components, design and workmanship. BS8215:1991. Design and installation of damp-proof courses in masonry construction, and the relevant clauses in the Building Regulations.
 

Overview
Installation
Technical
Calculations
Data Sheet
 

Elimiates Cold Bridging
Fully Certified
1,000,000 + m/Linear Supplied

CFC/HCFC Free
Rigid Lengths Ease Installation
Meets NHBC and Robust Standards