Follow us on Twitter Follow us on FaceBook Distributors' Merchandise Press Releases Links
Home
Enquiries
Suppliers
Downloads
Contact
Careers

Products Overview | Cavity Closers | Therma-close


General Purpose insulated cavity closer


Calculation method for assessing
Thermal Bridging at the edges of openings

Example
The diagram below shows a window jamb in a masonry cavity wall, with Therma-Close closing the cavity.
Robust details require a cavity closer with a minimum Thermal Resistance of 0.45m²K/W

Calculation of Thermal Resistance Path (R value)
This table shows the thermal resistance for each segment of the path ABCD. The thermal resistance for each segment is obtained by dividing the length of the path segment in metres by its thermal conductivity in W/mK

Path segments Length (m) Conductivity (W/mK) Resistance (m²K/W)
A - B
0.0275
0.12
0.23
B - C
0.030
0.029
1.034
C - D
0.040
0.770
0.052
Thermal Resistance Path ('R' value) = 1.316m²K/W
 

Overview
Installation
Technical
Calculations
Data Sheet
 

Cavity closer incorporating DPC
NHBC Approved
Fully Certified
Million’s of linear metres supplied

CFC/HCFC Free -
Environmentally Friendly
Waterproofs, insulates,
self locating
Can be made to fit any cavity width