Cavity Insulation Slab
|
Technical Information
Test Report No: 0207-L-07
EN 10286: Thermal insulating
products for building applications -
Determination of water vapour
transmission properties (1997-07).
Test Report No: 0207-L-07
EN 1609: Thermal insulating products
for building applications -
Determination of short term water
absorption by partial immersion,
method A (1997-01).
Test Report No: 0207-L-07
EN 12087: Thermal insulating
products for building applications -
Determination of long term water
absorption by immersion, method 1A
(1997-07).
Test Report No: 0207-L-07
EN1604: Thermal insulating products
for building applications -
Determination of dimensional stability
under specified temperature and
humidity conditions (1997-01).
Test Report No: 0207-L-07
EN 12667: Thermal performance of
building materials and products -
Determination of thermal resistance
by means of guarded hot plate and
heat flow meter method - Products of
high and medium thermal resistance
(2001-02).
Test Report No: 0207-L-07
EN822: Thermal insulating products
for building applications -
Determination of length and width
(1994-11).
Test Report No: 0207-L-07
EN823: Thermal insulating products
for building applications -
Determination of thickness(1995-05).
Test Report No: 0207-L-07
BS 5803-4: Thermal insulation for use
in pitched roof spaces in dwellings -
Part 4: Methods for determining
flammability and resistance to
smouldering (1985).
| Thickness |
Width |
Length |
Area |
Slabs
Per Pack |
Thermal
Conductivity |
Thermal Resistance |
| 65mm |
450mm |
1.2m |
9.72m² |
18 |
0.039 W/mk |
1.666 M²K/W |
| 75mm |
450mm |
1.2m |
8.64m² |
16 |
0.039 W/mk |
1.923 M²K/W |
| 85mm |
450mm |
1.2m |
7.56m² |
14 |
0.039 W/mk |
2.179 M²K/W |
| 100mm |
450mm |
1.2m |
6.48m² |
12 |
0.039 W/mk |
2.564 M²K/W |
|
 |
Quick, clean and easy
to install
|
 |
|
 |
 |
No protective clothing
|
 |
|
 |
 |
Free from floating
fibres
|
 |
|
 |
 |
Direct equivalent
to glass fibre insulation
|
 |
|
 |
 |
Totally recyclable |
 |
|
 |
|
 |
|
|
|
 |