Press Releases Links
Home
Enquiries
Suppliers
Downloads
Contact

Products Overview | Wall | Non-Itch Timber Frame Insulation

Timber Frame Insulation Slab


Calculations

The table below shows the U-values achieved using Non-Itch Timber Frame Insulation slabs placed between the studs.

Non-Itch Timber Frame Insulation Slabs including YBS Breather-Foil FR

Thickness Stud Thickness Thermal Conductivity U-value W/M²K
90mm 89mm 0.039 W/mk 0.33
90mm 89mm 0.0425 W/mk 0.34
140mm 140mm 0.039 W/mk 0.25
140mm 140mm 0.0425 W/mk 0.26

Non-Itch Timber Frame Insulation Slabs including standard breather membrane

Thickness Stud Thickness Thermal Conductivity U-value W/M²K
140mm 140mm 0.039 W/mk 0.28
140mm 140mm 0.0425 W/mk 0.31

 