Follow us on Twitter Follow us on FaceBook Distributors' Merchandise Press Releases Links
Home
Enquiries
Suppliers
Downloads
Contact
Careers

Products Overview | Cavity Closers | Therma-bridge Plus


Polyethylene Insulation DPC


Calculation method for assessing Thermal Bridging at the edges of openings

Example
The adjacent diagram shows a window jamb in a masonry cavity wall, with Therma-Bridge Plus closing the cavity.

Robust details require a cavity closer with a minimum Thermal Resistance path of 0.45m:²K/W.

Calculaion of Thermal Resistance Path (R value)
This table shows the thermal resistance for each segment of the path ABCDE. The thermal resistance for each segment is obtained by dividing the length of the path segment in metres by its thermal conductivity in W/mK

Path Segments
Length (m)
Conductivity
(W/mK)
Resistance
(m:²K/W)
A-B
0.0275
0.12
0.23
B-C
0.015
1.13
0.013
C-D
0.018
0.038
0.474
D-E
0.04
0.770
0.052
Thermal Resistance Path (R value) = 0.769m:²K/W

 

 

Overview
Installation
Technical
Calculations
Data Sheet
 

Elimiates Cold Bridging
Fully Certified
1,000,000 + m/Linear Supplied

CFC/HCFC Free
Rigid Lengths Ease Installation
Meets NHBC and Robust Standards