Therma-Bridge — Technical
Data
Total System Width (mm) |
Insulation Width (mm) |
For Return
Block (mm) |
DPC Length (metres) |
165 |
100 |
100 |
1.42, 2.50 or 5m Lengths |
225 |
150 |
140 |
1.42, 2.50 or 5m Lengths |
337 |
150 |
140/150 |
1.42, 2.50 or 5m Lengths |
450 |
150 |
140/150 |
1.42, 2.50 or 5m Lengths |
Other non-standard dpc and
insulation widths are also available
on request. Please contact us for details.
Performance Test Data of DPC
DPC to BS6515 (1984) High Performance Polyethylene
Performance Test
Data of Insulation
ESP70 (Expanded Polystyrene) to BS
EN 13163.
‘r’ value of product is 0.474 m:²K/W. (at
18mm thickness)
‘k’ value of Expanded
Polystyrene is 0.038 W/mK.
Recommendations
All work should be carried out in accordance
to BS5628:Part 3:1985.
Use of masonry, materials and components,
design and workmanship. BS8215:1991.
Design and installation of damp-proof
courses in masonry construction, and the
relevant clauses in the Building Regulations.
|