If used in a horizontal and
vertical situation 100mm of the
insulation should be cut/trowelled off the dpc prior to
the commencement of the
installation.
The exposed dpc should be
lapped onto the horizontal dpc,
the exposed edge of the
installation should then be butted
as tightly as possible onto the
top of the horizontally placed
Therma-Close.
Therma-Close can be
built-in as the work progresses.
Alternatively Therma-Close
can be tacked on the side of the
window frame, if the window is to
be built-in.
Therma-Close should be
positioned with the dpc facing
outwards.
The inner face of the
reveal to be dry-lined.
horizontal
Therma-Close should be
positioned at the cill/threshold
being held in place by the
locating clips.
The protruding dpc should be
lapped beneath the cill/threshold.
Therma-Close should be
positioned with the dpc facing
outwards.